Contains: 100 μm Zirconium Beads

Button Setting #1: 5 min. @ 1500 rpm

 

Protocol:

  • Spin down 2 ml of sample or cultured bacteria.
  • Decant the supernatant and resuspend the pellet in 500 μl of a suitable buffer.
  • Transfer the solution to a Bacteria Lysis Bead Tube.
  • Homogenize for 5 minutes at 1500 rpm (press preset button).
  • Centrifuge for 5 minutes at 12,000 × g.
  • Transfer the supernatant to a clean tube and store/process.

 

May be used for: bacteria/spores

 

Helpful Hints:

  • Increase the homogenization time if obtaining low DNA concentrations from gram positive bacteria.
  • Assays can be performed to assess optimal homogenization conditions.
Read More...


Yes! I am interested


Business Type Manufacturer, Exporter, Supplier
Brand Name Ohaus
Usage Lab

Preferred Buyer From

Location Worldwide

Product Number: 30391406 (100 each)

Contains: 1.4 mm Zirconium Beads

Button Setting#2: 2 min. @ 1500 rpm

 

Protocol:

  • For cultured cells or blood, centrifuge sample and decant supernatant. Resuspend the pellet in 500 μl of a suitable buffer and transfer to a Lysing Bead Tube. For solid samples, place approximately 50 mg in a Lysing Bead Tube and 500 μl of a suitable buffer. Homogenize for 2 minutes at 1500 rpm (press present button).
  • Remove debris by centrifuging for 5 minutes at 12,000 × g.
  • Transfer the supernatant to a clean tube for processing or storage.

 

May be used for: soft tissues (e.g., brain, adipose, liver, spleen); cultured cells and blood, as well as thin sections of fungal thallus and soft plant material

Read More...


Yes! I am interested


Business Type Manufacturer, Exporter, Supplier

Preferred Buyer From

Location Worldwide

Product Number: 30391404 (100 each)

 

Contains: 400 μm Zirconium Beads

Button Setting #1: 5 min. @ 1500 rpm

 

Protocol:

  • Spin down 1 ml of sample or cultured yeast.
  • Decant supernatant and resuspend the pellet in 500 μl of a suitable buffer.
  • Transfer the yeast solution to a Yeast Lysing Bead Tube.
  • Homogenize for 5 minutes at 1500 rpm (press preset button).
  • To remove debris, centrifuge for 5 minutes at 12,000 × g.
  • Transfer the supernatant to a clean tube for processing or storage.

 

May be used for: yeast, algae, spores

 

Helpful Hints: 

  • Longer processing times may be required to homogenize smaller yeasts (i.e. Pichia).
  • Homogenization can be evaluated by comparing homogenized yeast to a non-homogenized sample under a microscope. Yeast cells that are cracked open will appear dark gray.